Skip to Content
  • English (UK) Français Português
  • +254 724 795849 / 0717791925 / 0707902068
  • Follow us
Maesio Pharmaceuticals Limited
  • 0
    My Cart
  • 0
    Wishlist
  • Sign in
  • Get my quoteGet quote0→
  • Home
  • Shop
  • Company
    • Blog / Health Guides
    • About us
    • Jobs
    • Appointment
  • Contact us
  • Weekly Discounts
  • Promotions
  • Packages & kits
  • Shop by need
  • Health News & Alerts
  • WhatsApp us
Maesio Pharmaceuticals Limited
  • 0
  • 0
    • Home
    • Shop
    • Company
      • Blog / Health Guides
      • About us
      • Jobs
      • Appointment
    • Contact us
    • Weekly Discounts
    • Promotions
    • Packages & kits
    • Shop by need
    • Health News & Alerts
  • +254 724 795849 / 0717791925 / 0707902068
  • Follow us
  • English (UK) Français Português
  • Sign in
  • Contact Us
Free Nairobi deliveryOn orders above KSh 10,000Secure paymentsDPO PAYVisaMastercardM-PESA · Airtel MoneyAmerican ExpressDiners ClubInternational shippingDelivery through DHLPay in KSh or USDLocal & international ordersEasy returnsEligible items · Terms apply
Free Nairobi deliveryOn orders above KSh 10,000Secure paymentsDPO PAYVisaMastercardM-PESA · Airtel MoneyAmerican ExpressDiners ClubInternational shippingDelivery through DHLPay in KSh or USDLocal & international ordersEasy returnsEligible items · Terms apply
OUR GROWING COMMUNITY4.9 / 5 · 266 Google reviews ↗14K+ Facebook followers ↗
  1. All products
  2. Medical Supplies
  3. Diagnostic & Examination Equipment
  4. Fundus Cameras
  5. APPA Fundus Camera
  6. Fundus Cameras
Pricelist: Default Pricelist
Default
Pricelist: Default Pricelist
Default
APPA Fundus Camera

APPA Fundus Camera

(0 review)

APPA Fundus Camera Price in Kenya – Non-Mydriatic / Mydriatic Retinal Camera with FFA

Product Overview

The APPA Fundus Camera (Non-Mydriatic / Mydriatic with FFA) is a professional ophthalmic imaging system designed for colour retinal photography and fundus fluorescein angiography. It combines routine retinal imaging with specialized angiographic examination in one diagnostic workstation.

Manufactured under the APPA range by Appasamy Associates, the instrument is suitable for ophthalmology departments, retina clinics, eye hospitals and specialist diagnostic facilities.

Also known as the APPA FFA Fundus Camera, APPA Retinal Camera, Non-Mydriatic Fundus Camera with Fluorescein Angiography or Digital Retinal Imaging System, the equipment helps eye-care professionals capture and document images of the retina, macula, optic disc and retinal blood vessels.

The camera supports non-mydriatic and mydriatic fundus photography, allowing retinal imaging with or without pharmacological pupil dilation according to the patient's condition and clinical requirements.

Its integrated Fundus Fluorescein Angiography (FFA) functionality supports the visualization of retinal circulation following intravenous administration of fluorescein dye by appropriately trained clinical personnel.

Fluorescein angiography provides information about blood flow, vascular leakage, areas of abnormal perfusion and other retinal vascular changes. These findings can assist ophthalmologists in evaluating retinal conditions and planning appropriate management.

The APPA Fundus Camera uses a digital imaging system to acquire retinal photographs and angiographic images for examination, documentation and follow-up.

Published APPA product information describes high-quality DSLR-based image acquisition and an optional tilting arrangement. The exact imaging sensor, field of view, resolution and software configuration should be confirmed for the supplied model.

The APPA Fundus Camera with FFA is intended for professional clinical use, combining routine colour fundus photography with advanced retinal vascular imaging capabilities.

Key Features

  • Integrated retinal imaging system: Combines colour fundus photography and fluorescein angiography.

  • Non-mydriatic photography: Supports selected retinal examinations without pupil dilation.

  • Mydriatic photography: Allows imaging following appropriate pupil dilation.

  • Fundus Fluorescein Angiography: Supports assessment of retinal vascular circulation.

  • Digital retinal photography: Captures images for clinical review and documentation.

  • DSLR-based image acquisition: Described in published APPA product material.

  • Retinal vessel visualization: Supports assessment of retinal vascular abnormalities.

  • Macular imaging: Provides images relevant to macular examination.

  • Optic disc imaging: Supports documentation of optic nerve head appearance.

  • Angiographic image sequences: Supports evaluation of dye transit and retinal vascular changes.

  • Image storage and review: Supports organized clinical documentation.

  • Tilting configuration: An available option described in APPA documentation.

  • Clinical workstation design: Suitable for specialized ophthalmic examination environments.

  • Software-assisted workflow: Supports management and review of captured images, depending on configuration.

APPA Fundus Camera Price in Kenya

The APPA Fundus Camera with FFA price in Kenya depends on the exact model, imaging configuration, included computer, software, examination table, installation arrangements and warranty.

Factors Affecting the Price

Fundus Camera Configuration

The colour photography model and the FFA-equipped model have different capabilities.

Digital Imaging System

The camera sensor, imaging optics and acquisition components affect the equipment configuration.

FFA Functionality

The angiography package requires suitable imaging hardware, optical filters, software and acquisition controls.

Computer and Software

Confirm whether the quotation includes a computer, monitor, software licences and image management tools.

Examination Table

The fundus camera may require a compatible powered or fixed examination table.

Installation and Training

Professional installation, calibration checks and operator training are important.

Warranty and Maintenance

Confirm service support, spare components and software maintenance arrangements.

Order Online – APPA Fundus Camera with FFA Kenya

Product DetailDescription
Product NameAPPA Fundus Camera with FFA
ManufacturerAppasamy Associates
Product CategoryOphthalmic Diagnostic Imaging
Instrument TypeDigital Fundus Camera
Colour Fundus PhotographyYes
Non-Mydriatic ImagingYes
Mydriatic ImagingYes
Fluorescein AngiographyYes
Image AcquisitionDigital / DSLR-Based
Retinal ImagingYes
Macular ImagingYes
Optic Disc ImagingYes
Angiography SoftwareConfirm
Computer and MonitorConfirm
Examination TableConfirm
Image Export / IntegrationConfirm
WarrantyConfirm
SupplierMaesio Pharmaceuticals Limited

Order Online: https://www.maesiopharmaceuticals.co.ke/shop

Buy APPA Fundus Camera with FFA in Nairobi

The APPA Retinal Camera with FFA is suitable for healthcare facilities requiring routine fundus photography alongside advanced retinal vascular imaging.

Suitable Healthcare Facilities

  • Ophthalmology departments.

  • Eye hospitals.

  • Retina specialist clinics.

  • Diabetic eye-care centres.

  • Hospital retinal imaging departments.

  • Specialist ophthalmic diagnostic centres.

  • Ophthalmology training facilities.

  • Clinical research departments.

Main Functions of the APPA Fundus Camera

1. Non-Mydriatic Fundus Photography

Non-mydriatic imaging allows retinal photographs to be captured without routine pharmacological dilation where sufficient pupil size and image quality permit.

This can be useful during selected clinical examinations and retinal screening programmes.

2. Mydriatic Fundus Photography

Mydriatic imaging is performed after appropriate pupil dilation.

Dilation may improve visualization in patients with small pupils or when a more comprehensive examination is required.

3. Fundus Fluorescein Angiography (FFA)

FFA involves intravenous administration of fluorescein dye followed by sequential retinal imaging.

It helps clinicians assess retinal vascular circulation, leakage, staining and abnormal vascular patterns.

4. Retinal Image Documentation

The system captures retinal photographs that can be reviewed, compared and stored in patient records.

5. Macular Imaging

Provides photographic documentation of the macular region.

6. Optic Disc Imaging

Supports observation and documentation of the optic nerve head.

7. Retinal Vascular Assessment

Angiographic imaging supports the evaluation of selected vascular abnormalities.

How the APPA Fundus Camera Works

The instrument uses ophthalmic illumination, specialized imaging optics and a digital image acquisition system to photograph the back of the eye.

During colour photography, the camera captures images of the retina through the pupil.

During fluorescein angiography, a qualified healthcare professional administers fluorescein dye intravenously according to an established clinical protocol.

The camera then records sequential images as the dye passes through the ocular circulation.

General Examination Workflow

  1. Prepare the camera and verify its imaging functions.

  2. Confirm the patient's identity and requested examination.

  3. Position the patient correctly at the chin and forehead supports.

  4. Select the required imaging mode.

  5. Perform non-mydriatic or mydriatic colour fundus photography as appropriate.

  6. Align and focus the camera.

  7. Capture the required retinal images.

  8. For FFA, complete the prescribed pre-procedure clinical assessment and consent.

  9. Administer fluorescein intravenously using the appropriate clinical protocol.

  10. Capture the required angiographic image sequence.

  11. Review image quality and relevant findings.

  12. Save and document the examination results.

Important: Intravenous fluorescein angiography is a medical procedure requiring appropriate staffing, screening, monitoring and emergency-response readiness.

Clinical Applications

Diabetic Retinopathy Assessment

Colour fundus photography documents visible retinal abnormalities. FFA may assist evaluation of vascular leakage, non-perfusion and neovascular changes where clinically indicated.

Retinal Vascular Occlusions

Fluorescein angiography can help evaluate retinal circulation and vascular abnormalities associated with retinal vein or artery occlusions.

Macular Disorders

The camera supports imaging of the macular region, with angiography providing additional vascular information in selected conditions.

Age-Related Macular Degeneration

May assist the assessment of suspected neovascular changes when fluorescein angiography is clinically appropriate.

Retinal Vascular Leakage

FFA supports visualization of abnormal dye leakage and staining.

Optic Disc Assessment

Colour images provide documentation of the optic disc as part of broader ophthalmic examination.

Treatment Follow-Up

Serial retinal images can assist clinicians in monitoring selected findings over time.

APPA Fundus Camera with FFA vs Colour-Only Fundus Camera

FeatureAPPA with FFAAPPA Colour-Only Camera
Colour Fundus PhotographyYesYes
Non-Mydriatic ImagingYesYes
Mydriatic ImagingYesYes
Fluorescein AngiographyYesNot Listed
Retinal Vascular Dye ImagingYesNo
IV Fluorescein RequiredFor FFA OnlyNo
Clinical ApplicationColour Photography and AngiographyColour Retinal Photography

The FFA-equipped model is intended for facilities that require both routine retinal photography and angiographic assessment.

Non-Mydriatic vs Mydriatic Imaging

FeatureNon-MydriaticMydriatic
Pupil DilationNot Routinely RequiredRequired
Imaging ConditionsDepends on Pupil Size and Media ClarityDilation Can Improve Imaging Access
Clinical UseSelected Screening and ExaminationMore Detailed Examination When Indicated
Patient PreparationUsually SimplerRequires Appropriate Dilation Protocol
Image QualityPatient-DependentMay Improve in Some Circumstances

Fundus Photography vs Fluorescein Angiography

FeatureColour Fundus PhotographyFFA
Image TypeColour Retinal PhotographFluorescence-Based Vascular Images
IV ContrastNoYes
Retinal AnatomyYesYes
Vascular Leakage AssessmentLimitedYes
Circulation AssessmentLimitedYes
Primary PurposeStructural DocumentationVascular Evaluation
Clinical MonitoringAccording to IndicationRequires Procedure-Specific Monitoring

Benefits of the APPA Fundus Camera with FFA

Combined Diagnostic Functions

Provides colour retinal photography and fluorescein angiography in one system.

Retinal Image Documentation

Supports recording of retinal structures and visible abnormalities.

Vascular Imaging Capability

FFA provides information beyond conventional colour photography.

Flexible Examination Modes

Supports non-mydriatic and mydriatic photography.

Specialist Clinical Applications

Useful for ophthalmology departments and retinal assessment services.

Follow-Up Imaging

Supports comparison of selected findings over successive examinations.

How to Choose an APPA Fundus Camera in Kenya

Selection FactorWhat to Confirm
ManufacturerAppasamy Associates
Exact Model NumberConfirm
Colour Fundus PhotographyYes
Non-Mydriatic ModeYes
Mydriatic ModeYes
FFAYes
Camera ResolutionConfirm
Field of ViewConfirm
Minimum Pupil DiameterConfirm
Camera SensorConfirm
Focus AdjustmentConfirm
Fixation TargetsConfirm
Fluorescein Imaging FiltersConfirm
Angiography RecordingConfirm
Software LicenceConfirm
Computer / MonitorConfirm
PACS / DICOM IntegrationConfirm
Examination TableConfirm
Electrical RequirementsConfirm
InstallationConfirm
Operator TrainingConfirm
WarrantyConfirm

APPA Fundus Camera Quotation in Kenya

Quotation RequirementDetails
ProductAPPA Fundus Camera with FFA
QuantityRequired Units
ManufacturerAppasamy Associates
Model / RevisionConfirm
Colour PhotographyRequired
Mydriatic / Non-MydriaticRequired
FFA HardwareRequired
FFA SoftwareRequired
Computer and MonitorConfirm
Image StorageConfirm
Data ExportConfirm
Examination TableConfirm
Fixation AccessoriesConfirm
Power AccessoriesConfirm
InstallationConfirm
Operator TrainingConfirm
WarrantyConfirm
DeliveryNairobi or Another Kenyan Location

Installation and Maintenance

Install the camera in a suitable ophthalmic examination room.

Provide a stable examination workstation and compatible electrical supply.

Follow the manufacturer's installation and calibration instructions.

Protect optical components from dust, moisture and mechanical damage.

Clean patient contact surfaces between examinations.

Maintain the digital acquisition system and associated computer according to the approved maintenance schedule.

Check image storage, backups and software access regularly.

Arrange qualified servicing if image capture, focus, illumination or angiography functions become defective.

Clinical Safety and Limitations

The APPA Fundus Camera is intended for trained ophthalmic professionals.

Fundus images require appropriate clinical interpretation.

Non-mydriatic operation does not guarantee that all patients can be photographed without dilation.

Fluorescein angiography involves an intravenous dye and carries risks, including nausea, allergic reactions and, rarely, severe hypersensitivity reactions.

FFA should only be performed when clinically indicated, with appropriate patient assessment, informed consent, trained personnel and emergency facilities.

The device does not replace OCT, OCT angiography, visual field testing, tonometry or comprehensive clinical examination when these are indicated.

Frequently Asked Questions About APPA Fundus Camera with FFA

What is the APPA Fundus Camera?

It is an ophthalmic imaging system used to photograph the retina and, in the FFA-equipped configuration, perform fluorescein angiography.

What is the APPA Fundus Camera price in Kenya?

The price depends on the model, imaging package, software, computer, accessories, installation and warranty.

Where can I buy an APPA Fundus Camera in Nairobi?

You can enquire about the APPA Fundus Camera through Maesio Pharmaceuticals Limited.

Who manufactures the APPA Fundus Camera?

It is associated with Appasamy Associates.

What does FFA mean?

FFA stands for Fundus Fluorescein Angiography.

Does the APPA Fundus Camera support non-mydriatic photography?

Yes.

Does it support mydriatic photography?

Yes.

Does it include fluorescein angiography?

The FFA-equipped product listing includes this function.

What is the difference between the APPA colour camera and FFA camera?

The FFA model includes angiography capabilities in addition to colour retinal imaging.

Can the APPA Fundus Camera examine the retina?

Yes. It captures images of retinal structures.

Can it photograph the macula?

Yes.

Can it photograph the optic disc?

Yes.

Can it assist in diabetic retinopathy assessment?

Yes. Colour photography and clinically indicated angiography provide information useful in diabetic retinal assessment.

Can it assess retinal vascular leakage?

FFA can support evaluation of abnormal vascular leakage.

Is fluorescein dye required for normal colour photography?

No.

Is fluorescein dye required for FFA?

Yes, conventional FFA requires intravenous fluorescein administration.

Does FFA require trained medical personnel?

Yes. It is an invasive imaging procedure requiring appropriate clinical supervision and safety measures.

Can FFA cause allergic reactions?

Yes. Allergic and other adverse reactions can occur, occasionally including severe reactions.

Can the camera be used without pupil dilation?

Yes, for suitable examinations where image quality and pupil conditions permit.

Does the camera produce digital images?

Yes.

Does it use a DSLR camera?

Published APPA product literature describes DSLR-based image acquisition. Confirm the exact camera configuration.

Does the camera include a computer?

Computer inclusion should be confirmed in the quotation.

Can images be stored electronically?

Yes. The imaging workflow supports digital documentation.

Does the camera support DICOM?

DICOM integration has not been verified for Maesio's exact supplied model.

What is the camera's resolution?

The exact sensor resolution must be confirmed.

What is the field of view?

The field of view for the supplied version must be confirmed.

Can the camera diagnose retinal diseases automatically?

Automated AI diagnosis has not been established for this product. Clinical interpretation remains necessary.

Does it replace an OCT scanner?

No. Fundus photography and OCT provide different types of information.

Does it measure eye pressure?

No.

Is it suitable for retina clinics?

Yes.

Can hospitals request a quotation?

Yes. Healthcare facilities can request a quotation through Maesio Pharmaceuticals Limited.

What should I confirm before purchasing?

Confirm the exact model, FFA hardware and software, sensor specification, included computer, examination table, installation and warranty.

Does Maesio Pharmaceuticals arrange delivery outside Nairobi?

Yes. Delivery to other locations in Kenya can be discussed according to product availability and order requirements.

APPA Fundus Camera Product Specifications

SpecificationDetails
Product NameAPPA Fundus Camera with FFA
ManufacturerAppasamy Associates
Brand / Product RangeAPPA
Product CategoryOphthalmic Diagnostic Imaging
Instrument TypeDigital Retinal Camera
Colour Fundus PhotographyYes
Non-Mydriatic ImagingYes
Mydriatic ImagingYes
Fundus Fluorescein AngiographyYes
Digital Image AcquisitionYes
DSLR ImagingDocumented in APPA Product Literature
Retinal PhotographyYes
Macular PhotographyYes
Optic Disc PhotographyYes
Angiographic Image AcquisitionYes
Optional Tilting ArrangementDocumented
Exact Model NumberConfirm
Camera ResolutionConfirm
Field of ViewConfirm
Minimum Pupil DiameterConfirm
Working DistanceConfirm
Fixation SystemConfirm
IlluminationConfirm
AutofocusConfirm
Angiography FiltersConfirm
Image Acquisition SoftwareConfirm
FFA Software LicenceConfirm
Computer / MonitorConfirm
DICOM / PACS CompatibilityConfirm
Examination TableConfirm
Power SupplyConfirm
DimensionsConfirm
WeightConfirm
Operator TrainingConfirm
InstallationConfirm
WarrantyConfirm
SupplierMaesio Pharmaceuticals Limited
AvailabilitySubject to Confirmation

Technical specification note: The confirmed product capabilities are colour fundus photography, non-mydriatic and mydriatic imaging, and FFA. Published material for the APPA camera family references DSLR acquisition and a tilting option. Numerical camera specifications have been left unassigned because the exact model and revision have not been established.

Related Products

  1. Digital Refractor with Arm (PDR-7000)

  2. Refractor Head Manual AA-201 with Arm

  3. SLT Laser 208 with slit lamp, motorized table & SLT Laser lens

Buy APPA Fundus Camera and Retinal Imaging Equipment in Kenya

The APPA Fundus Camera with FFA combines digital retinal photography with fluorescein angiography for specialized ophthalmic diagnostic applications.

Its non-mydriatic and mydriatic imaging capabilities make it suitable for eye hospitals, retina clinics and ophthalmology departments requiring retinal imaging and vascular assessment.

Maesio Pharmaceuticals Limited supplies fundus cameras, retinal diagnostic instruments, slit lamps and other ophthalmic equipment.

Order Online: https://www.maesiopharmaceuticals.co.ke/shop

3,619,200.00 KES 3,619,200.00 KES (Tax included)
Price on request
  • Packaging
Add to cart
Buy now
Add to wishlist
Enquire on WhatsApp ↗

Need several items or ordering for a facility?

Ask about a bulk quotation ↗

Delivery options · Returns information

Alternative Products

These other products might interest you

Customer Reviews

Equity Bank red logo

Pay with confidence.

Pay Maesio via M-PESA using Equity Paybill.

Paybill number247247
Account number253173

Account name: MAESIO PHARMACEUTICALS
Share your payment confirmation with your order or quotation number.

Get payment assistance ↗
Payment is confirmed after verification by our Accounts team.

LICENSING & VERIFICATION

PPB Compliant:

We adhere to all Pharmacy and Poisons Board regulations to ensure safe and quality healthcare products.

MAESIO PHARMACEUTICAL LIMITED-OUTERING ROAD
Licence: BU2****7873 · Type: WHOLESALE
Status: VALID · Valid until 31 December 2026

View PPB wholesale register ↗

Search Maesio in the official public register.

CARE FOR YOU. SUPPLIES FOR BETTER CARE.

Your next order starts with a conversation.

Everyday essentials or a complete facility list. Our team is here to help.

Talk to Maesio ↗
Maesio Pharmaceuticals

Your pharmaceutical and medical supplies partner. For your home, your practice and your facility.

X

Explore the shop

  • Medical supplies
  • Medicines
  • Vitamins & supplements
  • Hospital furniture
  • Skin & personal care
  • Shop all products ↗

Here to help

  • Delivery information
  • FAQs & returns
  • Visit our stores
  • Contact us
  • About Maesio
  • Health & wellness journal
  • Privacy policy
  • Your wishlist

Let’s stay connected

0724 795 8490717 791 9250707 902 068EMAIL OUR TEAMsales@maesiopharmaceuticals.co.keinfo@maesiopharmaceuticals.co.keNAIROBI · KENYA · BEYOND

Nairobi delivery, countrywide dispatch and international shipping enquiries.

A little more from Maesio.

Subscribe for product updates, offers and news.

Thanks for registering!

Subscribe

© 2026 © 2026 Maesio Pharmaceuticals Ltd. All rights reserved.

Care for every day. Essentials for every facility.

DPO PAYM-PESAAirtel MoneyKSh / USD

Respecting your privacy is our priority.

Allow the use of cookies from this website on this browser?

We use cookies to provide improved experience on this website. You can learn more about our cookies and how we use them in our Cookie Policy.

Allow all cookies
Only allow essential cookies