Se rendre au contenu
  • English (UK) Français Português
  • +254 724 795849 / 0717791925 / 0707902068
  • Suivez-nous
Maesio Pharmaceuticals Limited
  • 0
    Mon panier
  • 0
    Liste de souhaits
  • Se connecter
  • Accueil
  • Boutique
  • Entreprise
    • Actualités
    • À propos de nous
    • Emplois
    • Rendez-vous
  • Contactez-nous
  • Réductions de la semaine
  • Promotions
  • Packages & kits
  • Shop by need
  • Contactez-nous sur WhatsApp
Maesio Pharmaceuticals Limited
  • 0
  • 0
    • Accueil
    • Boutique
    • Entreprise
      • Actualités
      • À propos de nous
      • Emplois
      • Rendez-vous
    • Contactez-nous
    • Réductions de la semaine
    • Promotions
    • Packages & kits
    • Shop by need
  • +254 724 795849 / 0717791925 / 0707902068
  • Suivez-nous
  • English (UK) Français Português
  • Se connecter
  • Contactez-nous
NOTRE COMMUNAUTÉ GRANDIT4.9 / 5 · 266 avis Google ↗14K+ abonnés Facebook ↗
  1. Tous les produits
  2. Fournitures médicales
  3. 200L Autoclave
  4. Fournitures médicales
Liste de prix: Default Liste de prix
Default
Liste de prix: Default Liste de prix
Default
200L Autoclave

200L Autoclave

(0 avis)

200L Autoclave Price in Kenya

A 200L Autoclave is a large-capacity steam sterilization machine designed to process suitable surgical instruments, hospital equipment, laboratory glassware, dressings, and other heat- and moisture-resistant materials using saturated steam under controlled pressure.

Also known as a 200-liter steam sterilizer, hospital autoclave 200 litres, 200L horizontal autoclave, industrial steam sterilizer, large-capacity medical autoclave, or laboratory steam sterilization machine, this equipment is commonly used in hospitals, central sterile services departments (CSSDs), operating theaters, laboratories, research institutions, and other facilities requiring substantial sterilization capacity.

The autoclave has a nominal chamber capacity of 200 liters, equivalent to 0.2 cubic meters. This refers to the sterilization chamber's volume, not the amount of water required or the weight of instruments that can be processed in one cycle.

A 200L autoclave operates by exposing compatible items to saturated steam under controlled conditions. When the correct cycle, loading configuration, steam quality, and exposure parameters are achieved, steam sterilization can inactivate microorganisms, including resistant bacterial spores.

Depending on the manufacturer, a 200-liter sterilizer may feature a horizontal or vertical chamber, automatic digital controls, temperature and pressure monitoring, drying programs, door safety interlocks, and a vacuum-assisted air-removal system.

For hospital surgical instruments, particularly wrapped, porous, and hollow loads, the sterilizer must have validated cycles suitable for those specific items. A 200-liter chamber alone does not establish that a machine can safely process every medical instrument.

The 200L autoclave price in Kenya depends on manufacturer, chamber construction, automatic control system, vacuum technology, steam generation method, electrical requirements, installation arrangements, validation services, and warranty coverage.

200L Autoclave Prices in Kenya

One directly comparable Kenyan advertisement was identified for an imported 200-liter steam sterilizer.

Kenyan Supplier

Product Description

Advertised Price

Equiplex Medical Supplies, Nairobi

Imported 200L steam sterilizer, stainless steel chamber, automatic temperature and pressure controls, safety locking system

KSh 680,000

This is the advertised price of another Kenyan seller, not Maesio Pharmaceuticals' selling price. The listing does not fully establish the sterilizer's exact manufacturer, vacuum-cycle capabilities, certification, installation scope, or included accessories.

A separate Kenyan supplier's October 2026 price guide places hospital and theatre steam sterilizers of various chamber sizes in a broad indicative range of KSh 180,000–760,000, excluding VAT and certain delivery costs. That range should not be interpreted as a confirmed price range specifically for 200-liter models.

200L Autoclave Price Comparison by Configuration

Autoclave Configuration

Main Price Considerations

200L Horizontal Autoclave

Chamber, control system, steam supply

200L Vertical Autoclave

Top-loading construction and accessories

200L Gravity-Displacement Sterilizer

Air-removal design and validated load types

200L Pre-Vacuum Autoclave

Vacuum pump, controls, and performance verification

200L Pulse-Vacuum Sterilizer

Multi-stage air removal and drying systems

200L Automatic Autoclave

Controller, sensors, safety interlocks

200L Hospital CSSD Autoclave

Validated surgical cycles and process documentation

200L Laboratory Autoclave

Laboratory load programs and containment requirements

Double-Door Pass-Through Autoclave

Door interlocking and installation requirements

Factors Affecting the 200L Autoclave Price in Kenya

  • Chamber Capacity and Construction
  • The chamber's size, stainless steel grade, wall thickness, insulation, and pressure-vessel construction affect manufacturing cost.
  • Air-Removal Technology
  • Gravity-displacement and vacuum-assisted sterilizers have different equipment requirements and validated load capabilities.
  • Control System
  • Digital controllers, touchscreen displays, programmable cycles, and electronic documentation functions may influence cost.
  • Steam Generator
  • Some models include an integrated electric steam generator, while others require an external steam source.
  • Drying System
  • Vacuum-assisted drying, heated jackets, and other drying features vary between models.
  • Door Design
  • Single-door and double-door pass-through sterilizers require different construction and installation.
  • Electrical Power
  • Large sterilizers may require dedicated three-phase electrical infrastructure and substantial power capacity.
  • Installation and Commissioning
  • Site preparation, connection work, calibration, commissioning, and performance qualification may be separate procurement costs.
  • Warranty and After-Sales Support
  • Service availability, spare parts, operator training, and preventive maintenance arrangements affect the total ownership cost.

Order Online – 200L Autoclave Kenya

Buy a 200L Autoclave in Kenya from Maesio Pharmaceuticals Limited for hospitals, central sterile services departments, surgical facilities, laboratories, research institutions, and healthcare establishments.

Product: 200L Autoclave – Large-Capacity Hospital and Laboratory Steam Sterilizer

Supplier: Maesio Pharmaceuticals Limited

Nominal Capacity: 200 liters

Sterilization Method: Saturated steam under pressure

Chamber Configuration: Confirm horizontal or vertical construction.

Chamber Material: Stainless steel; confirm the manufacturer's specified grade.

Operating Temperature: Model dependent. Some commercially available 200L machines specify an adjustable range up to 134°C.

Control System: Confirm automatic or programmable digital controls.

Vacuum System: Confirm availability and validated cycle capabilities.

Electrical Supply: Check voltage, phase, frequency, and power consumption.

Applications: Sterilization of manufacturer-approved medical and laboratory loads.

Installation: Confirm site assessment, installation, commissioning, and training arrangements.

Delivery: Nairobi and countrywide Kenya, with East African supply arrangements available by agreement.

Ordering Advice: Confirm the exact autoclave model, pressure-vessel specification, permitted load types, validated cycles, utilities, chamber dimensions, warranty, installation requirements, and service support.

Buy 200 Litre Autoclave in Nairobi

Hospitals and institutions looking to buy 200 litre autoclave in Nairobi should evaluate the sterilization requirements of their facility before choosing a machine.

A 200-liter autoclave represents a substantial equipment investment and may require dedicated installation space, electrical infrastructure, water connections, drainage, ventilation, and trained operators.

Typical Buyers

  • Public hospitals

  • Private hospitals

  • Referral hospitals

  • Central sterile services departments

  • Surgical centers

  • Medical laboratories

  • Pharmaceutical laboratories

  • University research laboratories

  • Veterinary hospitals

  • Biotechnology facilities

  • Manufacturing and quality-control laboratories

The correct machine depends on the type of material being processed and the applicable sterilization standards.

200L Steam Sterilizer for Sale in Kenya

A 200L steam sterilizer for sale in Kenya may use different designs and technologies despite having the same nominal chamber capacity.

Large Sterilization Chamber

The 200-liter chamber provides space for appropriately arranged instruments, trays, containers, and other manufacturer-approved items.

Stainless Steel Pressure Chamber

Many large-capacity autoclaves have stainless steel chambers designed to withstand their specified steam and pressure conditions.

Automatic Temperature Regulation

Selected models use electronic controllers and sensors to manage sterilization parameters.

Pressure Monitoring

Pressure gauges, sensors, and monitoring systems provide information about chamber operation.

Digital Control Panel

Some machines have touchscreen displays or programmable cycle controllers.

Door Safety Interlock

Safety mechanisms are designed to prevent unsafe operation or opening while the chamber remains pressurized.

Vacuum-Assisted Air Removal

Selected 200L models use vacuum pumps to remove air from loads before steam exposure.

Drying Function

Some machines incorporate programmed drying to support appropriate processing of wrapped surgical instruments.

Cycle Documentation

Printers or electronic recording systems may provide sterilization cycle records.

Safety Protection

Manufacturer-specific systems may include alarms and protection against excessive temperature, pressure, or inadequate water supply.

For example, Kenyan supplier Suremed lists a WS-200YV pulse-vacuum sterilizer with a 200L chamber, 115–134°C operating temperature range, stainless steel chamber, vacuum pump, and digital controls. These are specifications for that identified model, not automatically specifications of the Maesio autoclave.

Large Capacity Autoclave Supplier in Kenya

Choosing a reliable large capacity autoclave supplier in Kenya is important because hospital steam sterilizers require more than simple equipment delivery.

Maesio Pharmaceuticals Limited supplies hospital equipment, laboratory products, surgical instruments, sterilization equipment, and medical consumables to healthcare facilities across Kenya and East Africa.

For a 200-liter hospital autoclave, procurement should include consideration of the manufacturer's specifications, available technical support, installation requirements, and ongoing maintenance.

Customers can explore medical equipment and laboratory supplies through www.maesiopharmaceuticals.co.ke.

What to Confirm With Your Autoclave Supplier

  • Exact manufacturer and model number

  • Chamber volume of 200 liters

  • Horizontal or vertical loading

  • Chamber dimensions and usable loading space

  • Chamber and pressure-vessel materials

  • Gravity or vacuum-assisted air removal

  • Validated load categories

  • Working temperatures and pressure ratings

  • Cycle durations and drying arrangements

  • Electrical voltage and phase

  • Water quality requirements

  • Drainage and ventilation requirements

  • Installation and commissioning arrangements

  • Calibration and qualification documentation

  • Operator training

  • Warranty, spare parts, and technical service

Hospital Autoclave 200 Litres Kenya

A hospital autoclave 200 litres in Kenya is particularly relevant to facilities processing larger volumes of reusable surgical instruments and other compatible items.

The machine may form part of a central sterile services department responsible for receiving, cleaning, inspecting, packaging, sterilizing, storing, and distributing reusable medical instruments.

Central Sterile Services Department (CSSD)

A CSSD may use large steam sterilizers to process validated surgical instrument loads from different hospital departments.

Operating Theaters

Hospitals with several operating theaters may require substantial sterilization capacity to support instrument availability.

Maternity and Surgical Facilities

Reusable instrument sets from appropriate obstetric and surgical procedures may require steam sterilization according to their manufacturers' instructions.

Specialist Hospitals

Facilities offering orthopedic, general surgical, or other specialist procedures may benefit from a large-chamber sterilizer when the throughput justifies it.

Important Capacity Consideration

A 200-liter chamber does not mean that 200 liters of instruments can be loaded without restriction.

The actual permissible load is determined by the chamber geometry, tray arrangement, maximum load weight, airflow requirements, and validated cycle specifications.

Laboratory Autoclave Price Kenya

A 200L laboratory autoclave may be used for sterilizing compatible laboratory materials such as glassware, certain culture media, and selected laboratory utensils.

However, laboratory sterilization and hospital surgical instrument sterilization may require different machine configurations.

Laboratory Glassware

Suitable glassware may be sterilized when approved by the manufacturer and processed using a validated cycle.

Culture Media

Some laboratory autoclaves have programs suitable for liquid media. These cycles require appropriate temperature control, loading limits, and controlled depressurization.

Research Laboratories

Large autoclaves may support research workflows involving substantial quantities of compatible materials.

Laboratory Waste Treatment

Certain sterilizers are designed and validated to decontaminate specified laboratory waste. A general-purpose hospital autoclave should not be assumed suitable for every hazardous or infectious waste stream.

Pharmaceutical Laboratories

Appropriate steam sterilizers may be used in pharmaceutical laboratory workflows, subject to process qualification and the applicable manufacturing or quality standards.

Important Restriction

Flammable solvents, sealed pressure-sensitive containers, volatile chemicals, and other incompatible materials must not be autoclaved unless the specific process and equipment are designed and approved for them.

Horizontal vs Vertical 200L Autoclave

Feature

Horizontal 200L Autoclave

Vertical 200L Autoclave

Loading Position

Front-loading

Typically top-loading

Chamber

Usually horizontal cylinder

Usually vertical cylinder

Loading Accessories

Trays, racks, carts, or baskets

Baskets or compatible holders

Floor Space

Model dependent

Model dependent

Handling

Front access

Requires top access

Vacuum Technology

Available on certain models

Model dependent

Drying Function

Available on certain models

Model dependent

Hospital Instrument Loads

Only if validated

Only if validated

Laboratory Loads

Model dependent

Model dependent

Which 200L Autoclave Should You Choose?

A horizontal unit may suit a busy CSSD handling wrapped instrument trays, provided the model has validated cycles for those loads.

A vertical unit may suit selected laboratory applications, depending on basket arrangement, load type, cycle validation, and ergonomic requirements.

Neither configuration is inherently suitable for every hospital or laboratory task.

Pre-Vacuum vs Gravity-Displacement Autoclaves

Feature

Pre-Vacuum Sterilizer

Gravity-Displacement Sterilizer

Air Removal

Vacuum-assisted

Steam displaces air

Vacuum Pump

Usually required

Usually not required

Hollow Instruments

Can be appropriate with validated cycles

Restricted by cycle and device compatibility

Porous Loads

Can be appropriate with validated cycles

Must be specifically validated

Wrapped Sets

Common application of validated pre-vacuum cycles

Depends on validated load specifications

Air Removal Testing

Bowie-Dick testing is relevant

Bowie-Dick test is not generally applicable

Cost

Often more complex

May be simpler

Suitability

Dependent on validated loads

Dependent on validated loads

For hospitals processing wrapped surgical packs and lumen-containing instruments, verified load and cycle compatibility matters more than the autoclave's nominal chamber size.

200L Autoclave vs 100L vs 300L

Feature

100L

200L

300L

Nominal Chamber Capacity

100 liters

200 liters

300 liters

Relative Volume

50% of 200L

Reference

150% of 200L

Suitable Throughput

Facility dependent

Facility dependent

Facility dependent

Installation Needs

Model dependent

Model dependent

Model dependent

Electrical Requirements

Model dependent

Model dependent

Model dependent

Purchase Cost

Configuration dependent

Configuration dependent

Configuration dependent

A 200L sterilizer has twice the nominal chamber volume of a 100L model, but it does not necessarily process twice as many surgical trays per cycle.

Throughput depends on usable chamber dimensions, permissible load weight, loading racks, cycle duration, drying time, and turnaround procedures.

Technical Specifications of a 200L Autoclave

The following is an example of a published WS-200YV pulse-vacuum model offered by a Kenyan supplier. It illustrates one possible configuration rather than establishing the exact specifications of Maesio's product.

Parameter

WS-200YV Example

Chamber Capacity

200L

Chamber Dimensions

Ø515 × 1,000 mm

Maximum Working Temperature

134°C

Operating Temperature Range

115–134°C

Working Pressure

0.22 MPa

Sterilization Time Setting

0–99 minutes

Drying Time Setting

0–99 minutes

Power Rating

10 kW

Electrical Supply

380V, 50Hz

Equipment Dimensions

1,400 × 750 × 1,740 mm

Gross / Net Weight

460 / 370 kg

Air Removal

Vacuum pump

Chamber Construction

Stainless steel

Model-specific example from the WS-200YV specification, published by Suremed Medical Supplies Kenya. The indicated time ranges are selectable settings, not recommended sterilization exposure times.

Understanding Sterilization Temperature

Common steam sterilization temperatures include 121°C and 132–134°C, depending on the device, load, and validated cycle.

A sterilizer capable of reaching 134°C does not automatically guarantee sterility. Successful processing depends on correct steam penetration, exposure conditions, drying, monitoring, and appropriate load preparation.

Understanding Working Pressure

The pressure rating describes the machine's operating conditions. It should never be confused with the chamber's maximum allowable design pressure or independently used to determine a sterilization cycle.

Understanding a 10 kW Electrical Rating

A 10 kW unit represents a substantial electrical load. Buyers should verify the facility's power supply, protective devices, wiring, and dedicated electrical installation requirements with qualified professionals.

Key Features of a Large-Capacity Hospital Autoclave

High-Capacity Steam Chamber

A 200L chamber provides a substantial working volume for appropriate sterilization loads.

Automated Cycle Controls

Selected systems manage defined cycle phases using programmable electronics.

Stainless Steel Construction

Appropriate stainless steel provides corrosion resistance and a cleanable chamber surface.

Temperature and Pressure Monitoring

Sensors and displays help operators observe cycle conditions.

Safety Door Interlocks

Interlocks help prevent operation or access under unsafe conditions.

Pre-Vacuum Technology

Selected models remove air mechanically before steam exposure.

Drying Programs

Certain hospital-grade systems include load-drying phases.

Cycle Records

Compatible systems may store or print operating data for sterilization documentation.

Protective Alarms

Depending on the model, alarms may identify low-water conditions, temperature deviations, pressure problems, or equipment faults.

Benefits of a 200L Steam Sterilizer

Supports Large Institutional Workloads

A sizable chamber can be useful for facilities that regularly process multiple compatible surgical instrument sets.

Centralizes Sterilization Activities

A suitably equipped CSSD can support consistent processing across hospital departments.

Enables Planned Instrument Rotation

A large autoclave can be integrated into institutional sterilization schedules, subject to actual throughput.

Supports Validated Infection-Prevention Processes

When properly installed, qualified, operated, and monitored, the sterilizer can form part of a comprehensive infection-prevention program.

Offers Different Application Configurations

Hospital and laboratory variants can support different types of steam-compatible loads.

Supports Documentation

Digital records or printers, when supplied, can assist with cycle traceability.

Long-Term Equipment Planning

A 200-liter sterilizer may be considered when projected workloads justify its size, utilities, maintenance, and operating costs.

200L Autoclave Installation Requirements

A hospital should complete a technical site assessment before purchasing.

Electrical Supply

Confirm voltage, number of phases, frequency, dedicated circuit capacity, and earthing.

Water Supply

Verify the quantity and quality of water required by the model. Certain steam generators require treated or demineralized water.

Drainage

Ensure that drains and discharge arrangements meet the manufacturer's requirements and local building regulations.

Floor Strength

Large autoclaves can be heavy. Verify the structural loading capacity of the installation area.

Access and Clearance

Measure doorways, corridors, service access, equipment footprint, and any required door swing or loading trolley clearance.

Ventilation

Provide appropriate heat and moisture management.

Steam Source

Confirm whether the machine uses an integrated generator or requires facility steam.

Technical Service

Plan for preventive maintenance, calibration, spare parts, and technical inspections.

Operator Training

Staff should receive model-specific training before independently operating the machine.

Installation Qualification and Performance Qualification

For regulated clinical and laboratory processes, request the appropriate documentation and qualification activities, which may include installation qualification (IQ), operational qualification (OQ), and performance qualification (PQ), according to applicable requirements.

Sterilization Monitoring and Quality Assurance

Large autoclaves should operate within a documented quality assurance program.

The CDC recommends a combination of mechanical, chemical, and biological monitoring to assess steam sterilization processes.

Monitoring Method

What It Evaluates

Mechanical Monitoring

Time, temperature, pressure, and recorded cycle parameters

Chemical Indicators

Exposure to specified sterilization conditions

Biological Indicators

Effectiveness against resistant test spores

Bowie-Dick Test

Air-removal performance in applicable dynamic-air-removal sterilizers

Load Records

Cycle identification, operator, load, and processing history

Routine Maintenance

Continued equipment condition and performance

Chemical indicator color change alone does not guarantee sterility. Biological monitoring is an important part of assessing the sterilization process.

For prevacuum sterilizers, air-removal testing is particularly important. The CDC recommends routine monitoring, including at least weekly biological indicators for steam sterilizers, with additional requirements for implant loads and certain validation situations.

Maintenance of a 200L Autoclave

Daily Checks

  • Review equipment status and error messages.

  • Check chamber cleanliness.

  • Inspect the door gasket where accessible.

  • Verify adequate required utilities.

  • Check printer paper or digital records where applicable.

  • Perform required monitoring tests according to the facility protocol.

Scheduled Preventive Maintenance

Qualified technicians may inspect the steam generator, valves, pressure sensors, temperature probes, vacuum pump, filters, seals, electrical components, and safety systems.

Calibration

Temperature and pressure measurement systems should be calibrated according to the equipment's maintenance schedule and applicable institutional requirements.

Pressure Vessel Safety

Inspection and certification obligations should be confirmed under the applicable Kenyan occupational safety and pressure equipment requirements.

Fault Management

If the equipment fails required performance testing or displays a critical fault, it should not continue routine sterilization until the problem has been appropriately evaluated and resolved.

Important Safety Warning

Never bypass a door interlock, pressure protection device, alarm, or other safety mechanism. Repairs should be performed by competent, authorized technicians.

Frequently Asked Questions

1. What is the 200L autoclave price in Kenya?

A comparable imported 200-liter steam sterilizer is advertised by Equiplex Medical Supplies at approximately KSh 680,000. The final price for another model will depend on its specifications, installation requirements, accessories, and warranty.

2. Where can I buy a 200 litre autoclave in Nairobi?

You can inquire through Maesio Pharmaceuticals Limited for large-capacity hospital and laboratory autoclaves.

3. What is a 200L autoclave?

It is a steam sterilizer with a nominal chamber volume of 200 liters.

4. What is a 200L autoclave used for?

It is used to sterilize compatible medical instruments, laboratory equipment, glassware, and other manufacturer-approved loads.

5. Are 200-liter autoclaves available in Kenya?

Yes. Kenyan suppliers advertise 200-liter steam sterilizers, including horizontal hospital models.

6. What is the difference between a hospital autoclave and a laboratory autoclave?

Hospital and laboratory autoclaves may differ in their validated cycles, loading arrangements, documentation, and permitted materials.

7. Are 200L autoclaves horizontal or vertical?

Both configurations exist, depending on the manufacturer.

8. Which is better: horizontal or vertical autoclave?

The correct configuration depends on load type, workflow, available space, and validated performance rather than loading orientation alone.

9. Can a 200L autoclave sterilize surgical instruments?

Yes, if the machine has validated cycles suitable for the particular instruments, packaging, and load configuration.

10. Can it sterilize wrapped surgical trays?

Only if the model and selected cycle are validated for wrapped instrument loads.

11. Can a 200L autoclave sterilize hollow instruments?

Only when the cycle is validated for the specific hollow devices and their manufacturers' instructions.

12. Can a 200L autoclave sterilize hospital dressings?

Certain models have validated textile or dressing cycles. Verify the exact load specification.

13. Can it sterilize laboratory glassware?

Yes, when the glassware is steam-compatible and the cycle is validated for the load.

14. Can a 200L autoclave sterilize culture media?

Some laboratory configurations have appropriate liquid cycles, but this capability must be confirmed.

15. Can it sterilize plastic products?

Only products specifically labeled as compatible with the selected steam sterilization conditions.

16. Can a 200L autoclave sterilize medical waste?

Only if the particular machine and process are approved and validated for the applicable waste category.

17. What temperature does a 200L autoclave reach?

Some commercially available 200L models operate at up to 134°C, but the exact range depends on the manufacturer.

18. What is the working pressure of a 200L autoclave?

Certain listed models specify approximately 0.22 MPa. That is a model-specific value, not a universal rating.

19. Does a 200L autoclave need three-phase power?

Many large electric models require three-phase power, but the electrical requirements depend on the specific machine.

20. What is the power consumption of a 200L autoclave?

Some models have approximately 10 kW rated power. Actual energy use depends on cycle duration, steam generation, and operating conditions.

21. Does every 200L autoclave have a vacuum pump?

No. Vacuum capability varies between models.

22. What is a pulse-vacuum autoclave?

It is a sterilizer that uses controlled vacuum and steam phases to remove air before the sterilization exposure.

23. Does a 200L autoclave have a drying function?

Many hospital-grade models do, but the function and its performance depend on the selected machine.

24. Are 200L autoclaves fully automatic?

Automatic models are available. The type and extent of automation should be confirmed.

25. Do 200L autoclaves include printers?

Some include printers or digital cycle recording, while others offer these as optional accessories.

26. What is a Bowie-Dick test?

It is a test used to evaluate air-removal performance in applicable dynamic-air-removal steam sterilizers.

27. What is a biological indicator?

It is a test system containing resistant microorganisms used to assess the effectiveness of a sterilization process.

28. Does reaching 134°C guarantee sterilization?

No. Correct exposure time, steam quality, air removal, load configuration, monitoring, and process validation are also essential.

29. How many instrument trays fit in a 200L autoclave?

The number depends on tray dimensions, maximum load weight, chamber layout, racks, and validated loading specifications.

30. Is a 200L autoclave suitable for a referral hospital?

It may be suitable, depending on the hospital's surgical workload, CSSD design, sterilization needs, and redundancy planning.

31. Can a 200L autoclave be used in a pharmaceutical laboratory?

Yes, if the model meets the laboratory's intended-use, qualification, and process validation requirements.

32. Does a 200L autoclave need installation?

Yes. Large-capacity equipment normally requires appropriate technical installation and commissioning.

33. Is operator training necessary?

Yes. Operators should be trained in the specific sterilizer's controls, load procedures, monitoring, and safety requirements.

34. Does a 200L autoclave need routine servicing?

Yes. Preventive maintenance and calibration should follow the manufacturer's recommendations and applicable requirements.

35. How often should biological indicator testing be performed?

The CDC recommends at least weekly biological monitoring for steam sterilizers, with further requirements for implant loads and certain validation situations. Local policies may impose additional testing.

36. Can hospitals order several 200L autoclaves?

Yes. Hospitals and institutions can request quotations based on model specifications, installation sites, quantities, and service requirements.

37. Does Maesio Pharmaceuticals deliver 200L autoclaves outside Nairobi?

Maesio Pharmaceuticals supplies healthcare equipment countrywide and can arrange East African deliveries, subject to equipment-specific transport and installation requirements.

38. What should I confirm before purchasing a 200L autoclave?

Confirm the model, chamber dimensions, load compatibility, validated cycles, voltage, power rating, water requirements, installation, training, warranty, maintenance support, and availability.

Product Specifications

Specification

Details

Product Name

200L Autoclave

Alternative Names

200 Liter Steam Sterilizer, Large-Capacity Autoclave, Hospital Steam Sterilizer, Laboratory Autoclave

Product Category

Sterilization Equipment / Hospital Equipment / Laboratory Equipment

Nominal Chamber Capacity

200 liters

Equivalent Volume

0.2 m³

Sterilization Method

Saturated steam under pressure

Chamber Orientation

Horizontal or vertical, model dependent

Loading Design

Front-loading or top-loading

Chamber Material

Typically stainless steel

Exact Stainless Steel Grade

Confirm manufacturer

Chamber Dimensions

Model dependent

Example Chamber Dimensions

Ø515 × 1,000 mm for certain horizontal models

Operating Temperature

Model dependent

Example Operating Range

115–134°C for the WS-200YV

Maximum Working Temperature

Model dependent; 134°C on certain models

Working Pressure

Model dependent

Example Working Pressure

0.22 MPa on certain models

Control System

Automatic, programmable, or manufacturer-specific

Display

Digital or touchscreen, depending on model

Air Removal

Gravity or vacuum-assisted, model dependent

Vacuum Pump

Optional/model dependent

Drying Function

Model dependent

Built-In Steam Generator

Confirm configuration

External Steam Compatibility

Model dependent

Electrical Supply

Manufacturer-specific

Example Electrical Supply

380V, 50Hz on certain horizontal models

Example Rated Power

10 kW on certain models

Sterilization Cycle Programs

Model and load dependent

Cycle Time

Defined by validated process

Adjustable Timer

Model dependent

Chamber Door

Single or optional double door

Safety Interlock

Verify selected model

Overpressure Protection

Verify pressure-vessel safety features

Overtemperature Protection

Manufacturer dependent

Low-Water Protection

Manufacturer dependent

Cycle Printer

Optional/model dependent

Digital Data Logging

Optional/model dependent

Bowie-Dick Test Program

Available on selected pre-vacuum models

Biological Indicator Monitoring

Required within facility quality assurance program

Chemical Indicator Monitoring

Required within facility quality assurance program

Suitable Surgical Loads

Only manufacturer-validated loads

Suitable Laboratory Loads

Only manufacturer-validated loads

Waste Decontamination

Only if approved and validated

Water Quality Requirement

Manufacturer dependent

Drainage Requirement

Manufacturer dependent

Installation Required

Yes

Operator Training

Required

Preventive Maintenance

Required

Calibration

According to specifications and facility requirements

Qualification Documentation

Confirm IQ/OQ/PQ applicability

Overall Dimensions

Confirm selected model

Equipment Weight

Manufacturer dependent

Manufacturer

Confirm selected product

Country of Manufacture

Confirm documentation

Applicable Standards

Verify model-specific conformity and local requirements

Warranty

Confirm supplier terms

Spare Parts

Confirm availability

After-Sales Service

Confirm arrangements

Stock Availability

Subject to confirmation

Delivery

Nairobi, countrywide Kenya, and East Africa by arrangement

The specifications above describe the 200L autoclave category and include clearly labeled examples from published manufacturers. They should not be treated as a confirmed datasheet for Maesio's particular 200L autoclave.

930 000,00 KSH 930 000,00 KSH (Toutes taxes comprises)

  • Conditionnement
Ajouter au panier
Acheter maintenant
Ajouter à la liste de souhaits
Se renseigner sur WhatsApp ↗

Vous commandez plusieurs articles ou pour un établissement ?

Demander un devis pour une commande groupée ↗

Options de livraison · Informations sur les retours

Alternative Products

These other products might interest you

Avis client :

À VOS CÔTÉS. DES FOURNITURES POUR MIEUX SOIGNER.

Votre prochaine commande commence par un échange.

Des essentiels du quotidien à la liste complète d’un établissement, notre équipe vous accompagne.

Contacter Maesio ↗
Maesio Pharmaceuticals

Votre partenaire en produits pharmaceutiques et fournitures médicales. Pour votre domicile, votre cabinet et votre établissement.

X

Explorer la boutique

  • Fournitures médicales
  • Médicaments
  • Vitamines et compléments
  • Mobilier hospitalier
  • Peau et soins personnels
  • Voir tous les produits ↗

À votre service

  • Informations de livraison
  • FAQ et retours
  • Visiter nos magasins
  • Contactez-nous
  • À propos de Maesio
  • Journal santé et bien-être
  • Politique de confidentialité
  • Votre liste de souhaits

Restons en contact

0724 795 8490717 791 9250707 902 068ÉCRIVEZ À NOTRE ÉQUIPEsales@maesiopharmaceuticals.co.keinfo@maesiopharmaceuticals.co.keNAIROBI · KENYA · ET AU-DELÀ

Livraison à Nairobi, expédition dans tout le Kenya et demandes d’envoi international.

Encore un peu de Maesio.

Abonnez-vous aux nouveautés, offres et actualités.

Merci pour votre inscription !

S’abonner

© 2026 Maesio Pharmaceuticals Ltd. Tous droits réservés.

Des soins au quotidien. Des essentiels pour chaque établissement.

DPO PAYM-PESAAirtel MoneyKSh / USD

Respecting your privacy is our priority.

Allow the use of cookies from this website on this browser?

We use cookies to provide improved experience on this website. You can learn more about our cookies and how we use them in our Cookie Policy.

Allow all cookies
Only allow essential cookies